ES (External Mount) Hydrostatic Contents Gauge System
The AJD ES (External Mount) Hydrostatic Contents Gauge System is a self-powered hydrostatic tank level gauge designed to provide continuous remote indication of liquid contents without electrical or pneumatic power. The externally mounted sensor is fitted at the base of the tank above the sludge level, providing accurate and reliable level measurement for marine and industrial applications. Suitable for diesel, fuel oil, biodiesel, lubricating oil, water, chemicals, AdBlue ® and urea.


Features
Self-powered operation – no electrical or pneumatic supply required
Serialized and individually identified
Continuous remote tank contents indication
Individually calibrated for tank geometry and liquid type
Specification
|
Measurement Principle |
Hydrostatic |
|
Pressure Range |
0 to 20 mH₂O |
|
Accuracy |
Better than ±1% Full Scale |
|
Power Supply |
None Required |
|
Sensor Connection |
¾” BSP |
|
Sensor Material |
Mild Steel with Viton diaphragm |
|
Optional Material |
Stainless Steel 316 |
|
Sensor Dimensions |
130mm Ø x 40mm |
|
Operating Temperature |
-30°C to +175°C |
|
Storage Temperature |
-30°C to +175°C |
|
Capillary – Internal (Optional) |
Copper sheathed in Terylene reinforced PVC tube Copper sheathed in Stainless Steel tube |
|
Capillary Length |
Up to 50m standard (100m with TX10 4-20mA) |
|
Minimum Bend Radius |
50mm |
|
Indicator Sizes |
100mm, 160mm or 250mm |
|
Calibration |
Litres, m³, Gallons, Depth or Weight |
|
Compatible Fluids |
Diesel, Fuel Oil, Biodiesel, Water, Chemicals, AdBlue®, Urea (When Fitted with compatible seals / sensor material) |
|
Weight |
5Kg |
Downloads
Datasheet
ES Hydrostatic Sensor Datasheet / Series 600 Datasheet
Tank Questionaries
AJD Tank Data Questionnaire
Bureau Veritas Certificate
Type Approval Certificate
Standards & Test Compliance


Marine type approval:
DNV and Bureau Veritas.
Environmental qualification:
Tested to meet or exceed IACS Unified Requirement E10 and relevant IEC 60945 requirements for equipment in a protected environment.
Individual environmental test standards:
IEC 60068-2-2 (dry heat);
IEC 60068-2-1 (low temperature);
IEC 60068-2-30 (damp heat/humidity;
IEC 60068-2-6 (vibration);
IEC 60092-504 (static and dynamic inclination);
IEC 60068-2-52 (salt mist).
Ingress protection:
ES sensor enclosure tested to IP68 in accordance with EN 60529:1992. 160 mm indicator tested to IP56 in accordance with EN 60529:1992.
Fire resistance:
ES coupling and metal-sheathed capillary tested generally in accordance with ISO 19921:2005, including exposure to an 800°C flame for at least 30 minutes.
Standards & Test Compliance
Marine type approval:
DNV and Bureau Veritas.
Environmental qualification:
Tested to meet or exceed IACS Unified Requirement E10 and relevant IEC 60945 requirements for equipment in a protected environment.
Individual environmental test standards:
IEC 60068-2-2 (dry heat);
IEC 60068-2-1 (low temperature);
IEC 60068-2-30 (damp heat/humidity;
IEC 60068-2-6 (vibration);
IEC 60092-504 (static and dynamic inclination);
IEC 60068-2-52 (salt mist).
Ingress protection:
ES sensor enclosure tested to IP68 in accordance with EN 60529:1992. 160 mm indicator tested to IP56 in accordance with EN 60529:1992.
Fire resistance:
ES coupling aand metal-sheathed capillary tested generally in accordance with ISO 19921:2005, including exposure to an 800°C flame for at least 30 minutes.
Accessories
Included as Standard:
– ES Hydrostatic Sensor,
– Stainless Steel Indicator,
– Capillary Assembly,
– Installation Instructions and Calibration Certificate.
Optional Extras:
– Ball Valve Isolation Kit,
– Male-Male Couplers,
– Detachable Capillary,
– Bulkhead Fittings,
– Dual Scale Dials,
– TX10 4-20mA Transmitter,
– TX400 Level Switch,
– DNV/BV Certification.
Additional Information
The ES sensor mounts externally via a ¾” BSP connection above the sludge level.
The capillary system is factory filled with dry nitrogen gas to eliminate moisture ingress and maintain long-term accuracy.
Every gauge is individually calibrated using customer tank data and can be supplied with scales in litres, m³, gallons, percentage full, depth or weight.
More Mechanical Tank Contents Gauges

E.S Sensor
Externally mounted. 3/4 BSP female connection. Stainless steel or mild steel body.

S.M Sensor
Externally mounted sensor. Stainless steel or mild steel body.

S.T Sensor
Internally mounted sensor. Stainless steel or mild steel body.

I.M Sensor
Internally mounted sensor. Stainless steel or mild steel body.
Need support with choosing a gauge?