Mechanical Tank Contents Gauges

ES (External Mount) Hydrostatic Contents Gauge System

The AJD ES (External Mount) Hydrostatic Contents Gauge System is a self-powered hydrostatic tank level gauge designed to provide continuous remote indication of liquid contents without electrical or pneumatic power. The externally mounted sensor is fitted at the base of the tank above the sludge level, providing accurate and reliable level measurement for marine and industrial applications. Suitable for diesel, fuel oil, biodiesel, lubricating oil, water, chemicals, AdBlue ® and urea.

Request a quote
DNV Certificate of Conformity
Bureau Veritas Certificate of Conformity
DNV and Bureau Veritas Type Approved

Features

Self-powered operation – no electrical or pneumatic supply required

Serialized and individually identified

Continuous remote tank contents indication

Individually calibrated for tank geometry and liquid type

Specification

Measurement Principle

Hydrostatic

Pressure Range

0 to 20 mH₂O 

Accuracy 

Better than ±1% Full Scale 

Power Supply

None Required 

Sensor Connection 

¾” BSP 

Sensor Material

Mild Steel with Viton diaphragm 

Optional Material

Stainless Steel 316

Sensor Dimensions

130mm Ø x 40mm

Operating Temperature 

-30°C to +175°C 

Storage Temperature 

-30°C to +175°C 

Capillary – Internal 

(Optional) 

Copper sheathed in Terylene reinforced PVC tube 

Copper sheathed in Stainless Steel tube 

Capillary Length 

Up to 50m standard (100m with TX10 4-20mA) 

Minimum Bend Radius 

50mm 

Indicator Sizes 

100mm, 160mm or 250mm 

Calibration 

Litres, m³, Gallons, Depth or Weight 

Compatible Fluids 

Diesel, Fuel Oil, Biodiesel, Water, Chemicals, AdBlue®, Urea (When Fitted with compatible seals / sensor material) 

Weight 

5Kg 

Downloads

Datasheet

ES Hydrostatic Sensor Datasheet / Series 600 Datasheet

Tank Questionaries

AJD Tank Data Questionnaire

Bureau Veritas Certificate

Type Approval Certificate

Standards & Test Compliance

DNV Certificate of Conformity
Bureau Veritas Certificate of Conformity

Marine type approval:

DNV and Bureau Veritas.

Environmental qualification:

Tested to meet or exceed IACS Unified Requirement E10 and relevant IEC 60945 requirements for equipment in a protected environment.

Individual environmental test standards:

IEC 60068-2-2 (dry heat);
IEC 60068-2-1 (low temperature);
IEC 60068-2-30 (damp heat/humidity;
IEC 60068-2-6 (vibration);
IEC 60092-504 (static and dynamic inclination);
IEC 60068-2-52 (salt mist).

Ingress protection:

ES sensor enclosure tested to IP68 in accordance with EN 60529:1992. 160 mm indicator tested to IP56 in accordance with EN 60529:1992.

Fire resistance:

ES coupling and metal-sheathed capillary tested generally in accordance with ISO 19921:2005, including exposure to an 800°C flame for at least 30 minutes.

Standards & Test Compliance

Marine type approval:

DNV and Bureau Veritas.

Environmental qualification:

Tested to meet or exceed IACS Unified Requirement E10 and relevant IEC 60945 requirements for equipment in a protected environment.

Individual environmental test standards:

IEC 60068-2-2 (dry heat);
IEC 60068-2-1 (low temperature);
IEC 60068-2-30 (damp heat/humidity;
IEC 60068-2-6 (vibration);
IEC 60092-504 (static and dynamic inclination);
IEC 60068-2-52 (salt mist).

Ingress protection:

ES sensor enclosure tested to IP68 in accordance with EN 60529:1992. 160 mm indicator tested to IP56 in accordance with EN 60529:1992.

Fire resistance:

ES coupling aand metal-sheathed capillary tested generally in accordance with ISO 19921:2005, including exposure to an 800°C flame for at least 30 minutes.

Accessories

Included as Standard:

– ES Hydrostatic Sensor,
– Stainless Steel Indicator,
– Capillary Assembly,
– Installation Instructions and Calibration Certificate. 

Optional Extras:

– Ball Valve Isolation Kit,
– Male-Male Couplers,
– Detachable Capillary,
– Bulkhead Fittings,
– Dual Scale Dials,
– TX10 4-20mA Transmitter,
– TX400 Level Switch,
– DNV/BV Certification. 

Additional Information

The ES sensor mounts externally via a ¾” BSP connection above the sludge level.

The capillary system is factory filled with dry nitrogen gas to eliminate moisture ingress and maintain long-term accuracy.

Every gauge is individually calibrated using customer tank data and can be supplied with scales in litres, m³, gallons, percentage full, depth or weight. 

More Mechanical Tank Contents Gauges 

E.S Sensor

Externally mounted. 3/4 BSP female connection. Stainless steel or mild steel body.

View Product

S.M Sensor

Externally mounted sensor. Stainless steel or mild steel body.

View Product

S.T Sensor

Internally mounted sensor. Stainless steel or mild steel body.

View Product

I.M Sensor

Internally mounted sensor. Stainless steel or mild steel body.

View Product
Contact us

Need support with choosing a gauge?

Trusted by marine and industrial professionals worldwide. We respond fast.

Request a quote
sales@ajdinstruments.co.uk
+44 (0)121 227 6981